SK Fiber Duplex Indoor Cable
Features
·Description |
2 fiber, Figure 8 structure, Φ900μm or Φ600μm Tight buffer fiber, Aramid yarn, PVC Jacket. |
·Standards |
· Comply with Standard YD/T 1258.3-2003, ICEA-596, GR-409, IEC794, etc; and meet the requirements of UL approval for OFNR and OFNP. |
Specification
·Cable Code
ZCC-III |
ZCC-II |
ZCC-I |
|
Cable Diameter (mm) |
(6.0±0.4)×(2.8±0.2) |
(4.2±0.4)×(2.0±0.2) |
(3.4±0.4)×(1.6±0.2) |
Cable Weight (kg/km) |
15.6 |
10.5 |
7.3 |
TBF Diameter |
900±50μm |
900±50μm |
600±50μm |
Tensile Strength |
Long term |
100N |
100N |
|
Short term |
200N |
200N |
||
Crush Resistance |
Long term |
200N/100mm |
100N/100mm |
|
Short term |
1000N/100mm |
500N/100mm |
||
Bending Radius |
Dynamic |
20×H ( Cable Axis) |
||
Static |
10×H ( Cable Axis) |
50/125μm |
62.5/125μm |
G.652 |
G.655 |
||
Attenuation(+20℃) |
@850nm |
≤3.5dB/km |
≤3.5dB/km |
||
@1300nm |
≤1.5dB/km |
≤1.5dB/km |
|||
@1310nm |
≤0.45dB/km |
≤0.50dB/km |
|||
@1550nm |
≤0.30dB/km |
≤0.50dB/km |
|||
Bandwidth (Class A) |
@850nm |
≥500MHz·km |
≥200MHz·km |
||
@1300nm |
≥1000MHz·km |
≥600MHz·km |
|||
Numerical Aperture |
0.200±0.015NA |
0.275±0.015NA |
|||
Cable Cut-off Wavelength λcc |
≤1260nm |
≤1480nm |
|||
Attenuation at temperature cycling Δα(-20℃~+85℃) |
@1300nm |
≤0.25dB/km |
≤0.25dB/km |
||
@1550nm |
≤0.10dB/km |
≤0.15dB/km |
Transport Temperature |
-20℃~+60℃ |
Storage Temperature |
-20℃~+60℃ |
Installation Temperature |
-5℃~+50℃ |
Operating Temperature |
-20℃~+60℃ |